首先要满足有关国家标准及其它有关标准的要求,还要符合合同的要求,通常山西干式变压器的合同应包括如下技术规范。
变几器的型式
相数、绕组数、是否是自耦、升压或降压
山西干式变压器的额定容量
对于三绕组山西干式变压器或自耦山西干式变压器应说明各绕组的额定容量,或在不同冷却方式下的额定容量。
山西干式变压器的冷却方式
油浸自冷;油浸风冷;强迫油循环风冷;强迫油循环水冷;强迫油导向循环风冷;强迫油导向循环水冷。
山西干式变压器的额定电压与调压方式
高压、中压或低压的额定电压,是有载调压或无励磁调压及其分按范围分接级。若为有载调压时应注明是中性点调压还是线端调压。
山西干式变压器的阻抗电压值。
联接组标号。
山西干式变压器的负载损耗、空载损耗及空载电流。
套管型电流互感器的技术数据。
额定频率。
安装地点的海拔高度。
以上要求应符合标准。
特殊要求等。
山西干式变压器设计计算的任务,就是根据上述技术规范,按照有关国家标准如《山西干式变压器》及《三相油浸式山西干式变压器技术参数和要求》和部标准等,确定山西干式变压器电磁负载、几何尺寸和电、热、机械方面的性能数据,以满足使用部门的要求。要有良好的工艺性,使其制造简单,产品的价格应便宜.要求设计者要综合考虑上述各种因素,进行多方案比较分析,选取佳方案。
Transformer design calculation tasks
First, to meet the relevant national standards and the requirements of other relevant standards, but also meet the requirements of the contract, usually transformer contract should include the following technical specifications.
Change a few device types
Number of phases, the number of windings, auto, step-up or step-down
The rated capacity of the transformer
Rated capacity of each winding three-winding transformer or autotransformer rated capacity, or in different cooling mode.
Transformer cooling
The oil from cold; air-cooled oil-immersed; forced oil circulation air-cooled; forced oil circulation water cooling; forced oil-oriented cycle air-cooled; forced oil-oriented loop water cooling.
Transformer rated voltage regulator
Rated voltage of high-voltage, medium-voltage or low voltage, load voltage regulation or no excitation voltage and its sub-range tap class. OLTC should indicate the neutral point regulator or line-side regulator.
The impedance of the voltage华盈非晶合金变压器有限公司 value of the transformer.
Connection symbol.
Transformer load loss and load loss and no-load current.
Technical Data bushing type current transformer.
Rated frequency.
The altitude of the installation site.
The above requirements should be consistent with the standards.
Special requirements.
The transformer design task, that is, according to the technical specifications in accordance with the relevant national standards, such as power transformers "and" three-phase oil-immersed power transformers technical parameters and requirements and standards, determine transformer electromagnetic load, geometry and electrical thermal and mechanical performance data to meet the requirements of the user departments. Have a good process, m传 真:0635-8888109aking it simple manufacturing, the price of the product should be cheap. Designers and comprehensive consideration of the above factors, comparative analysis of the multi-program, and select the best solution.